HP-8701-C3 | SH-3510
Transducer : HP-8701-C3
The transducer generates powerful and stable vibrations even for cutting that requires high power,and the profile is designed to endure long-term use.
SH-3510 specification click here
Specifications:HP-8701-C3
Frequency | 24kHz |
---|---|
Cord length | Up to 10 m |
Housing material | SUS303 / Resin (Duracon) |
Weight | 1160g |
Blade thickness | 1.0mm |
Applicable Materials
plate, sheet, film, and laminated material |
|
carbon fibers(CFRP) |
|
polyethylene fiber, molded articles containing carbon or glass fibers(GFRP) |
|
vulcanized latex, non-vulcanized latex, sheeting material, and tube |
Click here to download the dimensions and catalogs
Click here to apply for a test cut and Inquiries
Apply for test cut by fax
Apply for a test cutting by phone
Period of acceptance weekdays from 9:00 a.m. to 5:00 p.m.(Japan time)
Oscillator:SH-3510
Upgraded: Connection with PLC is now available
Factory improvement through DX/loT requires connection with various controllers and connection with PLC is now available besides the conventional relay control by ON/OFF switching. Standard installation of analog signal output for the load/amplitude and additional digital signals for each oscillation frequency/error type allow outputting more detailed data now.
Specifications:SH-3510
Frequency adjustment | Automatic tracking type | |
---|---|---|
Maximum output | 500W | |
Output adjustment | Step-less continuously variable type | |
Power requirement | Single phase 200 VAC, 50/60 Hz |
|
Power consumption | 1000VA | |
Outer dimension (mm) | 300W × 400D × 200H | |
Weight | 11kg | |
Function | Detection of error cause | |
External device connection function | Input | Oscillator ON/OFF, Amplitude adjustment. Error recovery |
Output |
DC analog output. Frequency pulse output. Load threshold warning, Power supply status monitor,Error detection |